AIRCHAL

AHUs & FANS

Company specializing in HVAC Systems

AIRCHAL produces top quality products , recognized by all since over 60 years. Today AIRCHAL is one of the leading Air Handling companies worldwide.

We have the required knowledge when considering air handling  for different applications and industries

Many machines sold under the label of York, Carrier and Flaktwoods were produced for and in the factory of Airchal.

Airchal is specialized in supplying quality :

  • Air Handling Units
  • Condensing Units
  • Packaged Solutions
  • Roof Tops
  • Dehumidification
  • Air Extraction
  • Fan Coil Units 

AIRCHAL considers customer trust and satisfaction as its key priorities. We obtained the ISO 9001 quality certificate in order to ensure continuous quality and finish.

PRODUCTS:

Air Handling Units

AIRCHAL AHU BIG Series

Airchal AHU’s up to 450.000 m³/h

Base Frame

U-shaped support bar, 60 – 160 mm Painted (standard RAL 9010 ) or galvanized steel,

Air Volume

Standard : 500-450.000 m³/h   In combination with gasburners, steam, water, air.

Thermal Properties

Thermal transmittance :T2 (0,98 W/m²K) Thermal bridging coefficient :TB2 (kb: 0,73) Bypass leakage :F9 Enclosure leaktightness :L1 +700 Pa => L1 (M): 0,07 l/(sm²) Enclosure leaktightness: L1 -400 Pa => L1 (M): 0,01 l/(sm²).

POLCC Clean Concept Polyester

This polyester concept is particularly suitable for hygienic applications or low-temperature(-35°C) applications. Our approach integrates self-supporting polyester panels, inducing high levels of rigidity and enhanced resistance over time.  Clean Concept technology optimises the performance of systems.

Air Handling Units POLCC Series up to -35°C (polyester)

Base frame :

120mm

Air volume

Standard : 2.000 – 55.000 m³/h Max: 330.000m³/h

Thermal properties

Thermal transmittance :T1 Thermal bridging coefficient :TB1 Bypass leakage :F9 Enclosure leaktightness :L1 +700 Pa => L1 (M): 0,07 l/(sm²) Enclosure leaktightness: L1 -400 Pa => L1 (M): 0,01 l/(sm²)

CC Clean Concept Standard

An Air Handling Unit (AHU) is used to re-condition and circulate air as part of a heating, ventilating and air-conditioning system

Air volume

Standard : 500-58000 m³/h

Thermal properties

Thermal transmittance :T2 Thermal bridging coefficient :TB2

Certification

AIRCHAL is certified ISO 9001, manufacture according to the EUROVENT norm (T2 TB2 specs). AIRCHAL has a line anti seismic and L1 T1 TB1 . Also adapted products for hospitals and nuclear power plants.Standard EN1886 is a part of a series of standards for air handling units used for ventilation and air conditioning of buildings.  

AIRCHAL considers customer trust and satisfaction as its key priorities. We obtained the ISO 9001 quality certificate in order to ensure continuous quality and finish.

AIR Fans

AIRCHAL offers a wide range of industrial fans for general air movement and special applications such as emergency high temperature smoke extract and pressurization. ATEX fans for explosive atmospheres and multistage options for increased pressure development.

  • Up to 400 °C working temperature
  • Volume up to 200.000 m³/h
  • Total pressure difference up to 23.000 Pa
  • ATEX

Material

  • Coated metal sheet
  • Galvanized metal sheet
  • Stainless Steel 1.4301 and 1.4571

 

Low Sound Level
Higher Efficiency